Serbia has registered 122 MW of capacity in the active-buyer category on its transmission system, signalling the emergence of a new class of industrial electricity customer able to combine consumption, generation and flexibility rather than operating only as a conventional buyer.
Elektromreža Srbije (EMS) chief executive Jelena Matejić disclosed the figure at the OIE SRBIJA 2026 conference, providing one of the clearest indications so far that the active-buyer model is moving beyond regulation and individual demonstration projects.
The development matters because an active buyer is fundamentally different from a conventional industrial electricity consumer.
A factory can consume power from the network while also producing electricity behind the meter, operating storage or controlling parts of its load. Depending on its contractual and technical arrangements, it can sell surplus electricity and participate in electricity markets directly or through an aggregator.
The industrial site therefore begins to resemble a portfolio.
For Serbia’s power market, the 122 MW figure remains small compared with total generation and demand, but it establishes a commercial base from which industrial flexibility could develop.
The opportunity is particularly relevant for electricity-intensive sectors with controllable production processes, including metals, chemicals, food processing, refrigeration, pumping, automotive manufacturing and other industries with significant variable loads.
From electricity bill to portfolio optimisation
The traditional industrial energy strategy focused on reducing the price paid for each MWh.
The active-buyer model changes the calculation.
A large factory may simultaneously have grid consumption, rooftop or ground-mounted generation, storage, flexible production equipment and several electricity contracts.
Its objective becomes optimisation of the combined position.
When market prices are low, the plant can increase consumption or charge storage.
When prices rise, it can reduce non-essential loads, consume locally generated electricity or release stored energy.
If production exceeds local demand, surplus electricity can potentially be sold.
The value therefore comes increasingly from managing the site’s net load, rather than simply negotiating a lower supply tariff.
That creates opportunities for energy-management companies, traders and aggregators.
Many industrial companies will not want to operate their own 24-hour trading desks.
Instead, they can outsource forecasting, nominations, imbalance management and dispatch optimisation while retaining control over their underlying production processes.
An aggregator could combine several factories whose individual flexibility varies during the day and offer the combined portfolio into electricity markets.
That turns industrial operating flexibility into a tradable resource.
Existing equipment becomes an energy asset
Much of the potential flexibility may not require new generation.
Industrial facilities already contain pumps, compressors, refrigeration systems, furnaces, HVAC equipment, water treatment, electric boilers and other loads whose operation can sometimes be shifted without affecting final output.
A food-processing plant, for example, may have refrigeration systems capable of reducing consumption temporarily while remaining inside required temperature limits.
A pumping system may operate earlier or later depending on reservoir levels.
Compressed-air systems may contain enough operational buffering to shift electricity demand for limited periods.
Individually, those adjustments may be small.
Aggregated across several sites, they can become system-relevant.
This is why the active-buyer model can develop differently from Serbia’s renewable generation market.
The value does not depend exclusively on constructing another wind or solar plant.
Part of the asset already exists inside the factory.
What is missing is often measurement, control and market access.
Smart control becomes the investment
For industrial customers, the next investment cycle could therefore be increasingly digital.
Flexible participation requires reliable metering, telemetry, automated control and a clear baseline showing what electricity consumption would have been without an activation.
An aggregator needs to know that a contracted 5 MW reduction is genuinely available before selling it.
It also needs to know how long the reduction can last, how quickly the factory can respond and when the load must recover afterwards.
Those constraints differ between industries.
A refrigeration facility may offer flexibility for relatively short periods.
A pumping operation could potentially shift several hours.
A continuous-process industrial plant may have very little ability to interrupt production but still contain smaller auxiliary loads that can respond.
The commercial advantage therefore lies in identifying and combining different types of flexibility.
Balancing responsibility remains central
Active participation also creates financial exposure.
An industrial company that changes its consumption or production profile affects the balance of the party responsible for its market position.
If that deviation is not forecast and settled correctly, flexibility revenues can be offset by imbalance costs.
This makes balancing responsibility central to the active-buyer model.
The value of an aggregator is not simply its ability to switch industrial loads on and off.
It must also coordinate schedules, market nominations and settlement.
That creates an advantage for companies already active in power trading and balancing.
Existing suppliers may use active-buyer services to deepen relationships with industrial customers.
Independent aggregators could compete by offering specialised optimisation without taking over the underlying electricity-supply contract.
Technology companies could provide control platforms while traders manage the wholesale-market position.
The result could be a new layer between Serbian industry and the electricity market.
Storage could strengthen industrial portfolios
Storage adds another dimension, although the active-buyer concept does not depend on batteries.
A factory with behind-the-meter storage can reduce grid demand during expensive periods, absorb on-site renewable production and potentially provide faster flexibility than industrial processes themselves.
The combination is more useful than either asset alone.
The factory provides predictable demand.
On-site generation reduces purchased electricity.
Storage smooths short-term deviations.
Flexible processes add additional controllability.
Together, these assets can operate as a small virtual power plant.
That could become particularly valuable as Serbia introduces more variable generation and balancing requirements increase.
122 MW is the starting point
The current 122 MW of transmission-connected active buyers is still an early-stage market.
The important question is how quickly that category expands and how much of the registered capacity becomes genuinely controllable.
A nominally active customer is not automatically a flexible one.
Industrial operators need sufficient economic incentive to allow production decisions to respond to electricity-market signals.
That requires transparent remuneration and confidence that participation will not interfere with the core business.
The next milestone will therefore not simply be another increase in registered MW.
It will be evidence that Serbian industrial sites are earning meaningful revenue from flexibility, surplus electricity and portfolio optimisation.
Once that happens, factories will stop being viewed only as large electricity consumers.
They will become part of Serbia’s dispatchable power-market infrastructure.